The work covered by this section consists of furnishing and installing bituminous coated corrugated steel culvert pipe, flared end sections, tees, elbows, and eccentric reducers of the size, type, and thickness called for on the plans at locations indicated on the plans or designated by the Engineer and to the lines and grades established by the Engineer. The work shall also include the construction of such joints and connections to other pipes, endwalls, and other drainage structures as may be necessary to complete the work shown on the plans.
All materials shall meet the requirements of Division 10 shown below:
Bituminous coated corrugated steel culvert pipe Subarticle 10324(A)
Bituminous coated corrugated steel flared end sections Subarticle 10324(B)
Bituminous coated corrugated steel pipe tees and elbows Subarticle 10324(C)
Bituminous coated corrugated steel eccentric reducers Subarticle 10324(D)
Metal pipe culverts, fittings, and all other accessories covered by this section shall be furnished by a supplier who has met the requirements of the Departments Brand Certification program for metal culvert pipes, and is listed on the Departments pre-approved list for suppliers of metal culvert pipe.
Pipe installation shall be in accordance with Section 300.
The quantity of pipe to be paid for will be the actual number of linear feet of pipe which has been incorporated into the completed and accepted work. Measurement will be made by counting the number of joints used and multiplying by the length of the joint. Where partial joints are used, measurement will be made along the longest length of the partial joint to the nearest 0.1 of a foot.
The quantity of flared end sections, tees, elbows, and eccentric reducers to be paid for will be the actual number of these items which have been incorporated into the completed and accepted work.
The quantities of pipe, measured as provided in Article 3244, will be paid for at the contract unit prices per linear foot for the various sizes and types of bituminous coated corrugated steel pipe culverts shown below. The quantities of flared end sections, tees, elbows, and eccentric reducers, measured as provided in Article 3244, will be paid for at the contract unit prices each for the various sizes and types of these items shown below.
Payment for foundation conditioning will be made as provided in Subarticle 3009(A).
Payment for providing select material will be made as provided in Subarticle 3009(B).
Payment for providing the bedding material will be made as provided in Subarticle 3009(C).
The above prices and payments will be full compensation for all work covered by this section, including but not limited to furnishing, hauling, and placing all pipe, flared end sections, tees, elbows, eccentric reducers, and other materials; making all joint connections; all excavation, bedding, and backfill; and cleaning out installed pipe.
Payment will be made under:
_______Inch Bituminous Coated C.S. Pipe Culverts,
Type ________,________Inch Thick Linear Foot
_______Inch Bituminous Coated C.S. Pipe Culverts,
Type ________,________Inch Thick, Elongated Linear Foot
_______Inch Bituminous Coated C.S. Flared End Sections,
Type _________, _________Inch Thick Each
_______Inch x _________Inch x __________Inch Bituminous Coated
C.S. Pipe Tees, Type ____________, ______Inch Thick Each
_____Inch Bituminous Coated C.S. Pipe
Elbows, Type ________,________Inch Thick Each
_____Inch x________Inch Bituminous Coated C.S.
Eccentric Reducers, Type __________,________Inch Thick Each