This document is part of Standard Specifications -- English Units.

The Table of Contents for this section is available.

SECTION 1115

FLASHING ARROW PANELS, TYPE C

1115-1 DESCRIPTION.

The work covered by this section consists of furnishing, placing, maintaining, relocating, and removing flashing arrow panels in accordance with the plans and specifications.

1115-2 MATERIALS.

All materials shall meet the requirements of Division 10 shown below:

Flashing Arrow Panels Article 1089-5

1115-3 CONSTRUCTION METHODS.

The provisions of Article 1105­3 will be applicable to the work covered by this section.

Arrow panels shall have the capability to display mode selections as shown in the plans.

Sequential arrow displays, left or right sequential chevron displays, or straight line caution displays shall not be used.

Flashing arrow panels shall be mounted on trailer truck, or other mobile unit.

1115-4 MAINTENANCE.

All maintenance shall meet the requirements of Article 1105­4.

1115-5 METHOD OF MEASUREMENT.

The quantity of flashing arrow panels to be paid for will be the maximum number of panels acceptably placed and in use at any one time during the life of the project as required by the contract.

1115-6 BASIS OF PAYMENT.

The quantity of flashing arrow panels, measured as provided in Article 1115­5, will be paid for at the contract unit price each for "Flashing Arrow Panels, Type C". Such price and payment will be full compensation for all work covered by this section, including but not

limited to furnishing, installing, operating, maintaining, relocating, and removing the flashing arrow panels.

Payment will be made under:

Flashing Arrow Panels, Type C Each