MEMORANDUM TO: Project Engineers
Project Design Engineers
FROM: W. J. Rogers, P.E.
State Bridge Design Engineer
DATE:November 24, 1997
SUBJECT:BULB TEE STANDARDS

The standards, PCG9, PCG10, PCG9SM, PCG10SM, have been revised to show a reduction in the bulb tee bottom flange widths of 1" (26 mm ) to 2’-2" (660 mm). This modification will enable prestressing plants to use their existing AASHTO Type IV bottom flange pallets in the production of the bulb tees.

The revised geometry results in a decrease in the gross area and moment of inertia of approximately 0.8 % and 1.3 %, respectively. Therefore, existing designs of bulb tees need not be re-analyzed.

This policy is effective with the February, 1998 letting. The Design Manual and NCBDS will be revised accordingly at a later date.


WJR/RGW/ap



Back to Structures Main Page
Last Updated: 8/11/98 by:Steven Rackley
E-mail Structure Design